Abstract: The friction coefficient is an important performance index of medical gloves, which is related to the convenience and slip resistance of gloves. In this paper, the friction coefficient of medical gloves samples is tested by the MXD-02 friction coefficient meter independently developed by Jinan Languang Electromechanical Technology Co., Ltd. , and the parameters, scope of application and test process of the equipment are briefly described, so as to solve the problem for the enterprise. The problem of the friction coefficient of medical gloves is provided for reference. Keywords: friction coefficient, slip resistance, convenience, medical gloves, latex gloves, rubber gloves, surgical gloves, inspection gloves, friction coefficient 1 , meaning Medical gloves are clean and hygienic, prevent fingers from being cut, prevent cross-infection of germs, etc., and are indispensable supplies in the medical and health field. The friction coefficient of the inner and outer surfaces of medical gloves should have different requirements. The inner surface is required to have a lower friction coefficient to meet the requirements of easy wearing of the gloves, to prevent the inner surfaces of the gloves from sticking together when they are in contact with each other, and it is difficult to open; the outer surface The friction coefficient should be high to prevent the medical staff from slipping when holding the medical device, and the device cannot be firmly held for corresponding operation. Therefore, strengthening the monitoring of the friction coefficient of medical gloves is an important factor to ensure the practicality of the gloves. 2 , the status quo Medical gloves are divided into two types of surgery and inspection. The performance requirements of surgical gloves are higher. The medical gloves are mainly divided into latex gloves and rubber gloves according to different materials. At present, most of the domestic medical gloves are latex gloves. The test of the friction coefficient of medical gloves can be carried out by referring to the standard GB 10006-1988 "Test method for friction coefficient of plastic film and sheet", which is applicable to the determination of the coefficient of friction of non-adhesive plastic films and sheets having a thickness of less than 0.2 mm . Figure 1 medical latex, rubber gloves 3 , test samples For a brand of surgical gloves, this paper mainly tests the friction coefficient of the inner surface of the sample. 4 , test equipment In this paper, Labthink MXD-02 friction coefficient tester surgical gloves coefficient of friction of the sample tested. Figure 2 MXD-02 friction coefficient meter 4.1 Test principle The basic basis of this test is the calculation formula of the friction coefficient - the ratio of the friction force to the pressure perpendicular to the contact surface. The device applies a certain vertical pressure to the sample by a weight of a known weight, and then passes the test piece to the large static friction force and sliding friction force generated during the relative sliding of the relatively stationary pair, thereby obtaining the static friction of the sample. Coefficient, coefficient of dynamic friction. 4.2 Equipment parameters 4.3 scope of use (1) This equipment is specially used to measure plastic film and sheet, aluminum foil, aluminum-plastic composite film, metal material composite tape for communication cable, metal products, rubber, paper, cardboard, woven bag, textile, non-woven fabric, conveyor belt The static friction coefficient and dynamic friction coefficient of materials such as wood, coating, brake pads, wipers, shoe materials, tires, etc. can also be used for the smoothness test of daily chemicals such as cosmetics and eye drops. (2) This equipment meets many national and international standards, such as ISO 8295 , GB 10006 , ASTM D1894 , TAPPI T816, etc. 5 , the test process (1) Three samples of 8 cm × 20 cm and 100 mm × 63 mm were cut from the surface of the sample to form three sets of samples. Do not touch the test surface of the specimen with your hands during the cutting process. (2) Take a piece of 8 cm × 20 cm sample, the inner surface of the sample is upward and fixed on the horizontal test bench. Take a piece of 100 mm × 63 mm , the inner surface of the sample is exposed ( that is, the outer surface is in direct contact with the slider ) , and it is fixed on the slider. During the process of fixing the specimen, the test surface of the specimen shall not be touched by hand. (3) Place the slider without impact on the specimen on the horizontal test bench to ensure that the test system of the equipment is not affected, and the test direction of the specimen is parallel to the moving direction of the slider. (4) Set the parameter information such as test speed and test stroke. Click the test option and the test starts. After the two samples are still for 15 s , the relative motion starts. (5) The equipment automatically records the change of the force value during the test, and calculates the static friction coefficient and the dynamic friction coefficient of the sample. (6) Repeat (2) ~ (5) until the test of the three groups of samples is completed. 6 , test results The dynamic and static friction coefficients between the inner surface and the inner surface of the three groups were 0.291 ( static ) , 0.265 ( moving ) , 0.283 ( static ) , 0.257 ( moving ) , 0.286 ( static ) , and 0.253 ( moving ) . 7 , conclusion MXD-02 friction coefficient meter is a professional testing equipment for testing the smoothness of materials. It has the advantages of high detection accuracy and good repeatability of test results. By monitoring the friction coefficient of medical gloves, it can ensure the use of gloves when in use. Convenience and practicality. In addition to the friction coefficient meter, Labthink can also provide you with a tensile tester for the tensile test of gloves, an oxygen transmission rate tester for films or containers for other pharmaceutical and medical device packaging, and a water vapor transmission rate tester. , heat sealing performance tester and other testing equipment, specific information about the equipment you can visit Jinan Languang company or call directly . The more you understand, the more you trust! Jinan Languang Electromechanical Technology Co., Ltd. is willing to enhance technical exchanges and cooperation with enterprises and institutions in the industry. Copyright statement: Article Copyright Jinan Languang Electromechanical Technology Co., Ltd., reprinted without permission!
Preservation tubes are swabs with disposable virus sampling tubes to collect DNA tests for disposable nasal flocking sterile medical transport.
Made of high-quality PP material, high chemical stability, high temperature sterilization, suitable for multi-channel pipettes and automatic machines. Square well, U-shaped bottom design ensures minimal sample residue. Molded letters and numbers for easy positioning. Complies with SBS regulations and can be stacked stably. Good sealing performance, the top of the plate is flat and uniform, maintaining an effective seal. Optional gamma radiation sterile, DNase and RNA enzyme free, pyrogen-free.
Stable performance, low price, the material has a strong electrostatic adsorption capacity, can provide customized plastic card color according to user requirements, good color consistency
Non-invasive, painless and easy to operate. Samples are non-contagious and can be transported safely.
Disposable sampling swabs,Sterile sampling swab,Medical grade disposable swab Jiangsu iiLO Biotechnology Co., Ltd. , https://www.iilogene.com